Additionally, paste this code immediately after the opening tag:
Electronic Surge Protection

Electronic Surge Protection

Surge Protector ESP 12 DC

Surge Protector ESP 12 DC

Application:
DC Power
Type:
Combined Type 2-3
Current:
-
Phase:
N.A.
Let through Voltage (Up):
190V
Voltage:
12V
In-line Resistance:
-
Installation:
Install in parallel, within the power distribution board or directly on the supply feeding the equipment
Description:
Combined Type 2 and 3 tested protector (to BS EN 61643) for use on DC systems to protect connected electronic equipment from transient overvoltages on the mains supply, e.g. control equipment. Available for 12, 24, 36 and 48 V DC systems. For use at boundaries LPZ 1 through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 24 DC

Surge Protector ESP 24 DC

Application:
DC Power
Type:
Combined Type 2-3
Current:
-
Phase:
N.A
Let through Voltage (Up):
190V
Voltage:
24V
In-line Resistance:
-
Installation:
Install in parallel, within the power distribution board or directly on the supply feeding the equipment
Description:
Combined Type 2 and 3 tested protector (to BS EN 61643) for use on DC systems to protect connected electronic equipment from transient over voltages on the mains supply, e.g. control equipment. Available for 12, 24, 36 and 48 V DC systems. For use at boundaries LPZ 1 through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 36 DC

Surge Protector ESP 36 DC

Application:
DC Power
Type:
Combined Type 2-3
Current:
-
Phase:
N.A
Let through Voltage (Up):
190V
Voltage:
36V
In-line Resistance:
-
Installation:
Install in parallel, within the power distribution board or directly on the supply feeding the equipment
Description:
Combined Type 2 and 3 tested protector (to BS EN 61643) for use on DC systems to protect connected electronic equipment from transient over voltages on the mains supply, e.g. control equipment. Available for 12, 24, 36 and 48 V DC systems. For use at boundaries LPZ 1 through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP 48 DC

Surge Protector ESP 48 DC

Application:
DC Power
Type:
Combined Type 2-3
Current:
-
Phase:
N.A
Let through Voltage (Up):
190V
Voltage:
48V
In-line Resistance:
-
Installation:
Install in parallel, within the power distribution board or directly on the supply feeding the equipment
Description:
Combined Type 2 and 3 tested protector (to BS EN 61643) for use on DC systems to protect connected electronic equipment from transient over voltages on the mains supply, e.g. control equipment. Available for 12, 24, 36 and 48 V DC systems. For use at boundaries LPZ 1 through to LPZ 3 to protect sensitive electronic equipment.