Additionally, paste this code immediately after the opening tag:
Electronic Surge Protection

Electronic Surge Protection

Surge Protector ESP LN

Surge Protector ESP LN

Application:
Telecom & Computer Line
Type:
-
Current:
0.3A
Phase:
-
Let through Voltage (Up):
13.5V
Voltage:
4V
In-line Resistance:
0 ohm
Installation:
Suitable for systems signalling on up to 8 wires of unshielded twisted pair cable - protects all 8 pins in each line –– Use to protect 1, 4, 8 or 16 lines Combined Category C, B tested protector (to BS EN 61643) suitable to protect equipment on twisted pair applications using Cat-5 wiring with RJ45 connectors. For use on lines running within buildings at boundaries up to LPZ 2 through to LPZ 3 to protect sensitive electronic equipment.
Description:
Combined Category C, B tested protector (to BS EN 61643) suitable to protect equipment on twisted pair applications using Cat-5 wiring with RJ45 connectors. For use on lines running within buildings at boundaries up to LPZ 2 through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP Cat-6

Surge Protector ESP Cat-6

Application:
Telecom & Computer Line
Type:
-
Current:
0.3A
Phase:
-
Let through Voltage (Up):
120V
Voltage:
5V
In-line Resistance:
1.5 ohm
Installation:
Connect in series with the network cable, either: – Near to where it enters or leaves the building, or – As it enters the network hub, or – Close to the equipment being protected This should be close to the system’s earth star point (to enable a good connection to earth).
Description:
Combined Category D, C, B tested protector (to BS EN 61643) suitable to protect twisted pair Ethernet networks, including Power over Ethernet (PoE), with RJ45 connections. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ 3 to protect sensitive electronic equipment.
Surge Protector ESP LN

Surge Protector ESP TN

Application:
Telecom & Computer Line
Type:
-
Current:
0.3A
Phase:
-
Let through Voltage (Up):
395V
Voltage:
296V
In-line Resistance:
4.4 ohm
Installation:
Connect in series with the telephone or ISDN line. These units are usually installed close to the equipment being protected and within a short distance of a good electrical earth.
Description:
Combined Category D, C, B tested protector (to BS EN 61643) suitable to protect telephony equipment plugged into a BT telephone (BS 6312), Modem (RJ11) or ISDN (RJ45) socket. For use at boundaries up to LPZ 0 to protect against flashover (typically the service entrance location) through to LPZ 3 to protect sensitive electronic equipment.